Re-analysis finds no reliable shear correction for GFRP-reinforced concrete beams
Source: Buildings, "Assessing Longitudinal Axial-Stiffness Transferability in Steel- and GFRP-Reinforced Concrete Beams: A Study-Aware Analysis of One-Way Shear Resistance", published 25 November 2026.
What the source says
Glass fibre rebar in concrete: statistical re-analysis of 82 stirrupless test beams from six programmes (48 GFRP, 34 steel) plus 29 T-beams. Axial stiffness was a fair first predictor of shear resistance, but no reliable GFRP correction emerged. DOI 10.3390/buildings16234732.
Allbase view
A desk study pooling 82 existing test beams, with no new testing, leaves glass fibre rebar shear design where it was. Nothing to act on yet; current GFRP design guidance still governs shear checks.
Our reading of the paper, not a statement from the source. Checked against the paper on 26 Nov 2026.